Herringbone is not a laying style that can be applied to any plank. The geometry needs planks that exist as a matching left and right pair, either cut that way or manufactured as an A/B set with the click profile on the correct edges.

That single requirement drives everything downstream: the split of the order, the waste, the labour time and the number of ways the job can go wrong. A supplier who quotes herringbone from a single-SKU price list is quoting a product that cannot be installed as a herringbone floor.

Herringbone and chevron are different products

The two patterns are routinely confused. In herringbone, rectangular planks are laid at 90 degrees to each other and the ends form a zigzag. In chevron, the plank ends are cut at an angle — most often 45 degrees, sometimes 60 — so neighbouring planks meet in a continuous V and the pattern reads as an arrow running down the room.

A chevron floor cannot be produced on site from herringbone planks by trimming the ends, because the click profile would be lost. A herringbone floor cannot be built from chevron planks either. The pattern has to be decided before the order, and the product ordered has to match it. The formats themselves are listed in our herringbone SPC range.

Setting out decides the finished floor, and it is the step most often skipped under time pressure. Four decisions have to be made on the floor, not in the van.

  • Direction. Herringbone reads as a strong diagonal. Running it along the long axis usually makes a room feel longer; running it across makes it feel wider. In a corridor, the wrong direction is obvious from the doorway.
  • Starting line. A centre line is normally the safest start, because it puts the adjustment at two opposite walls rather than at one. Dry-lay two or three rows along the proposed line and measure the border at all four walls before committing.
  • Border width. A sliver of 20 mm at one wall looks like an error and cannot be fixed later. The usual trade rule is to keep every border wider than about a third of a plank width, and to shift the setting-out line if it does not.
  • Module. The pattern repeats over a fixed block set by the plank dimensions. Finding that block on the floor is what lets the pattern be centred deliberately instead of ending wherever it ends.
PatternGeometryPlank neededTypical wasteLabour indexWhere it suits
Straight plankParallel rowsSingle SKUroughly 5–7%1.0Most rooms; the baseline cost
Herringbone90 degrees, zigzag endsLeft and right pairroughly 8–12%1.5–2.0Entrances, retail, living areas
Double herringboneTwo planks per legLeft and right pairroughly 10–15%2.0Larger rooms where the scale reads better
ChevronAngled ends, continuous VDedicated chevron productroughly 12–20%2.0Formal rooms and large open floors

The waste figures are trade estimates. A small or irregular room pushes them towards the top of the range; a large rectangular floor pulls them down.

Herringbone consumes two plank types in equal numbers, and the order has to reflect that. This is where most first-time buyers lose money.

Click herringbone is normally packed and shipped in pairs, with the left and right in the same carton or in paired cartons. If installers open boxes ad hoc and lay from whichever is nearest, the mix drifts. The job then stops with a stack of one hand left and an uninstallable area in the middle of the room. The fix is procedural: keep the pairs paired until the plank is laid, and count the remaining lefts and rights at the end of each day.

Waste is higher than a straight lay for three reasons. The perimeter cuts consume offcuts that rarely fit anywhere else. The 45-degree set-out produces triangular pieces that are unusable. And the pattern exposes any damaged plank, because a replacement has to match both its neighbour and the direction of its leg.

Two practical rules follow. First, order the whole job from one production batch; a top-up later is a different batch with a different colour cast, and in a pattern this visible the seam will show. Second, keep an attic stock of roughly 5% of the order. In a straight lay a spare carton is prudence; in herringbone it is the only way to repair a single damaged plank without replacing a visible area.

The sequence is close to a straight click installation until the first pattern row, and then it diverges.

  • Subfloor first. Rigid planks telegraph ridges rather than bend over them, so the usual tolerance — around 3 mm under a 2 m straightedge — should be met before anything is opened, and the subfloor should be clean and dry.
  • Underlay only if the plank has none. A plank with an attached backing already carries its designed layer. Adding a second compressible layer changes the joint behaviour, and the trade-offs are set out in our guide to SPC flooring underlayment.
  • Leave the expansion gap. Typically 8–10 mm at walls and around any fixed object, per the manufacturer's instruction. In herringbone the gap is easy to lose at the diagonal walls, because the border pieces are cut at an angle and the gap closes as they are tapped.
  • Build the first V, then work outwards. Click in the direction the profile allows and use a tapping block or pull bar on the long edge — never strike the click edge directly.
  • Check the pattern every few rows. A single reversed plank is nearly impossible to correct once two rows have been laid over it, and it is always visible in a photograph.
  • Plan the doorways. Undercut the frame rather than cutting the plank around it, and decide the transition profile before the last row, not after.

For a glue-down herringbone the logic is different: full-spread adhesive, correct trowel notch, respect the open time, and roll the floor. There is no expansion gap at the perimeter in the same sense, but the setting-out and the left-right balance are identical.

Six failure modes account for most complaints on herringbone floors, and five of them are decided before the first plank is laid.

  • An unbalanced pair. The job runs out of one hand mid-room. It is an ordering and handling problem, not a product defect.
  • Subfloor out of tolerance. The click joints open along a ridge, usually in a line that follows the pattern and looks like a manufacturing fault.
  • Border slivers. The setting-out line was never tested against all four walls, so one edge ends in a fragment.
  • A blocked expansion gap. Skirting fixed through the floor, or a door frame packed tight, converts normal movement into joint separation.
  • An underlay that is too soft. The plank deflects at the joint and the lock fatigues. The symptom appears months after handover.
  • Pattern drift. Rows gradually lose their 90-degree relationship because the first rows were not checked with a square. By the far wall the error is visible to a visitor.

None of these are solved by a better plank. They are solved by the setting-out, the order split and the subfloor, which is why the pattern is a procurement decision as much as an installation one.

How much extra flooring should I order for herringbone?

Plan on roughly 8 to 12 per cent above the measured area for a straightforward rectangular room, and towards 15 per cent where the room is small, irregular or set out diagonally. Add around 5 per cent as attic stock kept in the same batch. The estimate is a planning figure, not a guarantee: the actual figure depends on the setting-out and the number of cuts at the perimeter.

Can a standard click plank be laid in herringbone?

Not normally. The click profile has to sit on the correct edges for each leg of the pattern, which is why herringbone click products are made as a left and right pair. Square-edged glue-down planks can sometimes be cut and laid in herringbone, but the edge tolerance and the joint detail have to be checked with the supplier before the order, because a cut edge is not a factory edge.

Does herringbone take longer to install?

Yes. The extra setting-out, the angled border cuts and the need to alternate left and right planks typically add somewhere between 50 and 100 per cent to the installation time compared with a straight click lay, depending on the room. That labour cost belongs in the landed cost calculation, and it is often larger than the difference between two plank prices.

Planning a herringbone project?

Send the room dimensions, the direction you want and the destination market, and we will confirm the left and right split, the waste allowance and the installation sequence for the format you are considering.

Request a B2B Quote ↗